Auxiliary Machinery. Test 51

Auxiliary Machinery. Test 51

/
What is the meaning of the pressure indicated by NBP on this nozzle/flapper assembly ?
Question Image
This characteristic shows that only linear part a-b can be used. This means that the normal effective travel of the flapper is only _____ for the full measuring range.
Question Image
The plate heat exchanger is separated for cleaning, what should you do if the plates are thick with scale or other organic material ?
In this nozzle/flapper assembly (part of a pneumatic control system) at what distance away from the nozzle does the flapper need to be moved in order not to have any influence on the NBP (nozzle back pressure) ?
Question Image
What is the most common reason for malfunctioning or erratic functioning of a pneumatic nozzle/flapper assembly ?
Question Image
What is the ideal temperature to maintain the diesel oil daily tank and how is this achieved ?
Question Image
When using marine diesel oil with a density of about 0.87, what would be the inlet temperature of the fuel to the purifier ?
Question Image
For a low pressure boiler, testing shows the water chloride level to be 1000 PPM. What action would you take ?
Why is the stern tube header tank fitted above the sea water level ?
Question Image
What maintenance is required for an 'Auto-Kleen' knife type filter?